LEMON Manuals: Even more car manuals for everyone
Home >> Hyundai >> 1994 >> Scoupe Base, Automatic >> Repair and Diagnosis >> Engine Performance >> System >> Engine Controls - Tests W/Codes >> Self-Diagnostic System >> Actuator Control Sequence Procedure

Actuator Control Sequence Procedure

  1. Ensure ignition switch is in OFF position. Connect jumper wire to diagnostic connector terminal No. 10 and vehicle ground. See Figure . Turn ignition switch to ON position. Disconnect ground wire in 2.5-4.0 seconds. Actuator test should start. See ACTUATOR TEST SEQUENCE table.
  2. To proceed with next test, ground jumper wire for 2.5-4.0 seconds. If jumper wire is grounded longer than 4 seconds, test sequence will start from beginning. Continue to ground jumper wire until 3333 (end of output) is flashed.
ACTUATOR TEST SEQUENCE

Activated Component Sequence No. Flash Code
Injector No. 1 1 1312
Injector No. 3 2 1314
Injector No. 4 3 1313
Injector No. 2 4 1315
IAC Motor 5 1321
Purge Control Valve 6 1322