- Remove distributor cap, rotor and seal. Remove governor assembly. Remove vacuum control unit. Remove IC ignitor. Remove lead wire. Remove signal rotor shaft screw and 2 breaker plate retaining screws. Remove breaker plate assembly.NOTE: DO NOT clean grease off back of IC ignitor. It is necessary for heat transfer.
- Remove signal rotor shaft from signal rotor. Remove 2 spring retainers and springs with pliers. Remove governor weights. Mark drive gear location on distributor shaft.
- Place drive gear on a wooden block and remove drive gear roll pin using a pin punch. Remove drive gear and washer. Remove distributor shaft from housing.