On/Off Wipe Relay Control Circuit Test
- Ignition OFF, disconnect the on/off wiper relay.
- Verify that a test lamp illuminates when connected from battery voltage to the relay coil ground circuit terminal 86.
- If the test lamp does not illuminate test the ground circuit for an open/high resistance.
- Connect a test lamp between the relay coil control circuit terminal 85 and the ground circuit terminal 86.
- Ignition ON, operate the front wiper switch between low and off and verify that the test lamp turns on and off.
- If the test lamp is always ON, test the control circuit for a short to voltage. If the circuit tests normal, replace the BCM.
- If the test lamp is always OFF, test the control circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the BCM.
- If all circuits test normal, test or replace the relay.