Circuit/System Testing
WARNING: This page is about a different car, the 2009 GMC Canyon and 2009 Chevrolet Colorado. However, it is still accessible from the selected car via links, so may be relevant.
Backup Lamps Malfunction - Automatic Transmission
- Ignition OFF, disconnect the harness connector at the inoperative backup lamp.
- Ignition OFF, exterior lamps OFF, test for less than 5 ohms between the ground circuit terminal G and ground.
- If greater than the specified range, test the ground circuit for an open/high resistance.
- Connect the harness connector at the inoperative backup lamp.
- Ignition OFF, disconnect the harness connector at the backup lamp switch.
- Ignition ON, verify that a test lamp illuminates between the control circuit terminal A and ground.
- If the test lamp does not illuminate, test the control circuit for a short to ground or an open/high resistance.
- Verify that a test lamp does not illuminate between the control circuit terminal B and ground.
- If the test lamp illuminates, test the control circuit for a short to voltage.
- Connect a 15-amp fused jumper between the control circuit terminal A and the control circuit terminal B. Verify the backup lamps illuminate.
- If the backup lamps do not illuminate, test the control circuit terminal B for a short to ground or an open/high resistance. If the circuit tests normal, test or replace the inoperative backup lamp.
- If all circuits test normal, test or replace the backup lamp switch.
Backup Lamps Malfunction - Manual Transmission
- Ignition OFF, disconnect the harness connector at the inoperative backup lamp.
- Ignition OFF, exterior lamps OFF, test for less than 5 ohms between the ground circuit terminal G and ground.
- If greater than the specified range, test the ground circuit for an open/high resistance.
- Connect the harness connector at the inoperative backup lamp.
- Ignition OFF, disconnect the harness connector at the PNP switch.
- Ignition ON, verify that a test lamp illuminates between the control circuit terminal 11 and ground.
- If the test lamp does not illuminate, test the control circuit for a short to ground or an open/high resistance.
- Verify that a test lamp does not illuminate between the control circuit terminal 10 and ground.
- If the test lamp illuminates, test the control circuit for a short to voltage.
- Connect a 15-amp fused jumper between the control circuit terminal 11 and the control circuit terminal 10. Verify the backup lamps illuminate.
- If the backup lamps do not illuminate, test the control circuit terminal 10 for a short to ground or an open/high resistance. If the circuit tests normal, test or replace the inoperative backup lamp.
- If all circuits test normal, test or replace the PNP switch.