Installation Procedure
WARNING: This page is about a different car, the 2008 Cadillac STS. However, it is still accessible from the selected car via links, so may be relevant.
- Install the surge tank.
- Connect the low coolant sensor electrical connector.
- Install the surge tank nut.
Tighten: Tighten the nut to 9 N.m (80 lb in).
- Install the surge tank bolt.
Tighten: Tighten the bolt to 9 N.m (80 lb in).
- Connect the surge tank inlet hose to the surge tank.
- Using the J 38185 , reposition the hose clamp to secure the surge tank inlet hose. See Special Tools .
- Connect the surge tank outlet hose.
- Using the J 38185 , reposition the hose clamp to secure the surge tank outlet hose. See Special Tools .
- Connect the master cylinder fluid level sensor electrical connector.
- Fill the cooling system. Refer to Cooling System Draining and Filling (Static Fill) or Cooling System Draining and Filling (GE 47716) .
NOTE:
Refer to Fastener Notice
.
IMPORTANT:
Lubricate the inside diameters of the hoses with clean coolant prior to installation.