Enable Conditions

Condition Minimum Maximum
Engine speed [Engine Speed] 500 rpm -
12 volt battery voltage [Battery Voltage] 10 V -
Other Clutch pressure control solenoid valve A actual current value is 400 mA or more, or shift solenoid valve D is ON condition
Not while switching to parking position
Engine speed, 12 volt battery voltage, and other conditions in Enable Conditions should be satisfied continuous for at least 4.5 seconds