Variable Cylinder Management (VCM) Test: Test
NOTICE:
Use a borescope that meets the following requirements.
- Tip diameter is 9 mm (0.35 in) or less.
- There is lighting at the tip.
- Side shooting is possible.
- VCM - Test (VCM Inoperative State)
Preconditions
Figure 1
Procedure/Specifications
NOTICE:
Be careful not to drop the borescope accessories inside the cylinder bores.
1. Refer to figure 1.
Tool Details (Figure 1)
Name a Borescope (Commercially Available) Recommended model: Snap-on BK5600 DUAL55
Figure 2
2. Rotate the crankshaft pulley clockwise.
3. Make sure that the valves move. (Figure 2)
Specifications (Figure 2)
Specification The valve moves Result
- If it is abnormal, check that the slide pin in the valve lifter moves smoothly.
- VCM - Test (VCM Operation State)
Preconditions
- Cylinder Head Cover Area Parts Removed
- Spark Plugs
- Rocker Arm Oil Control Valve
Figure 1
Procedure/Specifications
NOTICE:
Be careful not to drop the borescope accessories inside the cylinder bores.
1. Refer to figure 1.
Tool Details (Figure 1)
Name a Borescope (Commercially Available) Recommended model: Snap-on BK5600 DUAL55
2. Check that the air pressure on the shop air compressor gauge indicates over 690 kPa (7.04 kgf/cm2 , 100.1 psi).
Figure 2
3. Install the air adapter to the inspection hole, then connect the air pressure regulator as shown. (Figure 2)
Figure 3
4. With the specified air pressure applied, rotate the crankshaft pulley clockwise. Make sure that the valves do not move. (Figure 3)
Specifications (Figure 3)
Condition Specification Apply the 441-490 kPa (4.50-5.00 kgf/cm2 , 64.0-71.1 psi) The valve does not move Result
- If it is abnormal, check that the slide pin in the valve lifter moves smoothly.
- Cylinder Head Cover Area Parts Removed
- Valve Lifter - Test
Preconditions
Procedure/Specifications
- Inspect the slide pin (a). Push on slide pin manually.
Specifications
Object Specification a Slide pin move smoothly. Result