Malfunction Threshold
The total value of the parking actuator valve stroke sensor A output voltage and the parking actuator valve stroke sensor B output voltage is 4.0 V or less, or 6.0 V or more for at least 1.0 second.
The total value of the parking actuator valve stroke sensor A output voltage and the parking actuator valve stroke sensor B output voltage is 4.0 V or less, or 6.0 V or more for at least 1.0 second.