Malfunction Threshold
One of these conditions is met for at least 0.09 second.
- The current value of clutch pressure control solenoid valve D is more than 1,150 mA (regardless of the duty output).
- The current value of clutch pressure control solenoid valve D is more than 75 mA when the duty output is 0 %.