DTC P0532: Inspection
A/C Pressure Sensor Inspection
NOTE: Since there is no direct method to test the component itself, troubleshooting is performed on the related components.
Test Procedure
- Preparation
- A/C pressure sensor connector (3P): disconnected
- Procedure
- Perform the inspection according to the following chart.
| (Disconnected) A/C pressure sensor connector (3P) female terminals | ||||
| IG Mode |
|
Normal Conditions | ||
| Unit output voltage inspection | ON | About 5.0 V | ||
| ON | About 5.0 V | |||
Results
- If it is normal, there is a problem with the A/C pressure sensor.
- If it is abnormal, there is a problem with other related components.
VCC6, PD_SENSOR Circuit Inspection
NOTICE:
Before disconnecting the PCM connector, jump the SCS line with the HDS, and wait more than 1 minute.
Test Procedure
- Preparation
- PCM connector B (72P): disconnected
- A/C pressure sensor connector (3P): disconnected
- Procedure
- Perform the inspection according to the following chart.
| (Disconnected)A/C pressure sensor connector (3P)female terminals | (Disconnected) PCM connector B (72P) female terminals | ||||
| IG Mode |
|
|
Normal Conditions | ||
| VCC6 open wire inspection | OFF | There is less than 1 Ω | |||
| PD_SENSOR shorted to ground inspection | OFF | There is more than 1 MΩ | |||
Results
- If abnormal, there is a problem in the circuit.
PCM Inspection
Test Procedure
- If the other inspection item(s) indicated a normal condition, then it is determined that the remaining PCM is the cause.
Results
- There is a problem with the PCM.