DTC P00B4: Inspection
ECT Sensor 2 Inspection
NOTE: Since there is no direct method to test the component itself, troubleshooting is performed on the related components.
Test Procedure
Unit output voltage inspection
- Preparation
- ECT sensor 2 connector (2P): disconnected
- Procedure
- Jump the ECT sensor 2 connector (2P) terminals No. 1 and No. 2 with a jumper wire.
- Turn the vehicle to the ON mode.
- Confirm the HDS [ECT Sensor 2 Voltage].
| (Disconnected) ECT sensor 2 connector (2P) female terminals | |
|
|
- Normal Conditions
- HDS [ECT Sensor 2 Voltage] value is less than 4.93 V .
Results
- If it is normal, there is a problem with ECT sensor 2.
- If it is abnormal, there is a problem with other related components.
TW_SENSOR, SG6 Open Wire Inspection
NOTICE:
Before disconnecting the PCM connector, jump the SCS line with the HDS, and wait more than 1 minute.
Test Procedure
- Preparation
- ECT sensor 2 connector (2P): disconnected
- PCM connector B (72P): disconnected
- Procedure
- Perform the inspection according to the following chart.
| (Disconnected) ECT sensor 2 connector (2P) female terminals | (Disconnected) PCM connector B (72P) female terminals | ||||
| IG Mode |
|
|
Normal Conditions | ||
| TW_SENSOR open wire inspection | OFF | There is less than 1 Ω | |||
| SG6 open wire inspection | OFF | There is less than 1 Ω | |||
Results
- If abnormal, there is a problem in the circuit.
PCM Inspection
Test Procedure
- If the other inspection item(s) indicated a normal condition, then it is determined that the remaining PCM is the cause.
Results
- There is a problem with the PCM.