DTC P0103: Inspection
MAF Sensor Inspection
NOTE: Since there is no direct method to test the component itself, troubleshooting is performed on the related components.
Test Procedure
DTC check
- Preparation
- MAF sensor/IAT sensor connector (4P): disconnected
- Procedure
- Jump the MAF sensor/IAT sensor connector (4P) terminals No. 1 and No. 2 with a jumper wire.
- Perform the confirmation procedure.
| (Disconnected) MAF sensor/IAT sensor connector (4P) female terminals | |
|
|
- Normal Conditions
- DTC P0102 is indicated.
Results
- If it is normal, there is a problem with MAF sensor/IAT sensor.
- If it is abnormal, there is a problem with other related components.
VCC11, FGP_E, SG11 Circuit Inspection
NOTICE:
Before disconnecting the PCM connector, jump the SCS line with the HDS, and wait more than 1 minute.
Test Procedure
- Preparation
- MAF sensor/IAT sensor connector (4P): disconnected
- PCM connector E (114P): disconnected
- Procedure
- Perform the inspection according to the following chart.
| (Disconnected) MAF sensor/IAT sensor connector (4P) female terminals | (Disconnected) PCM connector E (114P) female terminals | ||||
| IG Mode |
|
|
Normal Conditions | ||
| VCC11 open wire inspection | OFF | There is less than 1 Ω | |||
| FGP_E open wire inspection | OFF | There is less than 1 Ω | |||
| SG11 open wire inspection | OFF | There is less than 1 Ω | |||
| VCC11, FGP_E shorted wire to wire inspection | OFF | There is more than 1 MΩ | |||
| VCC11, SG11 shorted wire to wire inspection | OFF | There is more than 1 MΩ | |||
| FGP_E shorted to power inspection | ON | Not shorted | |||
Results
- If it is abnormal, there is a problem in the circuit.
VCC11 Shorted Wire Inspection
NOTICE:
Before disconnecting the PCM connector, jump the SCS line with the HDS, and wait more than 1 minute.
Test Procedure
- Preparation
- MAF sensor/IAT sensor connector (4P): disconnected
- PCM connector E (114P): disconnected
- Rocker arm oil pressure sensor connector (3P): disconnected
- Procedure
- Perform the inspection according to the following chart.
Refer to the Open/Shorted Wire Inspection Description for the method to inspect the shorted circuit below, then start to inspect according to circumstances.
- Perform the inspection according to the following chart.
| (Disconnected) MAF sensor/IAT sensor connector (4P) female terminals | ||||
| IG Mode |
|
Normal Conditions | ||
| VCC11 shorted to ground inspection | OFF | There is more than 1 MΩ |
Results
- If it is abnormal, there is a problem in the circuit.
PCM Inspection
Test Procedure
- If the other inspection item(s) indicated a normal condition, then it is determined that the remaining PCM is the cause.
Results
- There is a problem with the PCM.