DTC C1100-98

DTC C1100-98  : Electric Parking Brake Continuous Operations Detected

NOTE 

Confirmation Procedure Basic Condition:
  • 12 volt battery voltage 9 - 16 V

Operating Condition:

  • Start the engine.
  • Apply and release the parking brake several times.(This DTC is set when repeated use of the electric parking brake function causes electric parking brake actuator overheating.)
Execution Electric parking brake in operation
Duration About 1 minute
DTC Type
  • 1 drive cycle
  • Brake system indicator (amber) on
Fail Safe Action
  • None
Possible Cause
  • Electric parking actuator overheating
  • Electric parking brake actuator internal failure
  • VSA modulator-control unit internal failure