LEMON Manuals: Even more car manuals for everyone
Home >> Honda >> 2021 >> Insight EX >> Repair and Diagnosis >> Hybrid/Electric Powertrain >> Cooling Systems >> Electric Powertrain - Service Information >> Removal and Installation >> Battery Condition Monitor Module >> Installation

Battery Condition Monitor Module: Installation

WARNING: 

The power cables carry high voltage when the electric powertrain system is energized. To avoid serious injury from electrical shock, do not turn on the system with the power cables disconnected.

NOTE: 

The electric powertrain components are located in this area. The electric powertrain is a high-voltage system. You must be familiar with the electric powertrain system before working on or around it. Make sure you have read the electric powertrain service precautions before doing repairs or service.

  1. Battery Condition Monitor Module - Install 
  2. IPU - Install 
  3. Battery Condition Monitor Module Data - Write
    NOTE:  If the Read Data procedure was failed in 1st procedure of the removal (Battery Condition Monitor Module Data - Read), go to next procedure (Battery Condition Monitor Module - Install).

    1. Connect the HDS

    2. Select the Electric Powertrain system with the HDS.

    3. Select the HV Battery/HV Battery ECU Replacement.

    4. Select the HV Battery ECU Replacement, then select the Write Data, and follow the screen prompts.

    NOTE:  If the Write Data procedure is failed, this procedure is complete.

  4. Battery Condition Monitor Module - Update (When replacing)