Malfunction Threshold
One of these symptoms occurs:
- Symptom 1
The output temperature from the IGBT chip temperature sensor is more than 322 deg.F (161 deg.C) for at least 100 milliseconds.
- Symptom 2
The output temperature from the IGBT chip temperature sensor is more than 302 deg.F (150 deg.C) for at least 11 seconds.