DTC C0023-12  : Brake Diag Circuit ON Failure

NOTE: 

Confirmation Procedure Basic Condition:
  • 12 volt battery voltage above 10 V

With the Driving Pattern:

  • Turn the vehicle to the ON mode.
  • Wait 2 seconds or more without pressing the brake pedal.
Execution Regular Diagnosis
Duration About 2 seconds
DTC Type
  • 1 drive cycle
  • VSA indicator on
Fail Safe Action
  • Stop ACC function
  • Stop CMBS function
Possible Cause
  • Brake light relay failure
  • Short to ground between the VSA modulator-control unit and the brake light relay (BRAKE LAMP line)
  • Open between the PCM and the brake pedal position switch (STOP SW line)
  • PCM internal failure
  • VSA modulator-control unit internal failure