Key Interlock Solenoid Test: Test

NOTE:  SRS components are located in this area. Review the SRS component locations and the precautions and procedures before doing repairs or service.

  1. Column Cover - Remove
  2. Key Interlock Solenoid - Test
    GHH433846Courtesy of HONDA, U.S.A., INC.
    1. Turn the ignition switch to LOCK (0).

    2. Disconnect the connector (A).

    3. Turn the ignition key to ACCESSORY (I).

    4. Connect 12 volt battery power to steering lock connector terminal No. 1, and ground to steering lock connector terminal No. 4. Check that the ignition key cannot be turned to LOCK (0). Disconnect 12 volt battery power and check that the key can be turned to the LOCK (0) position and removed from the cylinder.

    5. If the key interlock solenoid does not work properly, the key interlock solenoid is faulty; replace the steering lock

    (B).

  3. All Removed Parts - Install
    1. Install the parts in the reverse order of removal.