Recirculation Control Motor Test
WARNING: This page is about a different car, the 2011 Honda Pilot, 2010 Honda Pilot, and 2009 Honda Pilot. However, it is still accessible from the selected car via links, so may be relevant.
NOTE:
Before testing, check for HVAC DTCs (see GENERAL TROUBLESHOOTING INFORMATION
).
- Disconnect the 7P connector from the recirculation control motor.NOTE: Incorrectly applying power and ground to the recirculation control motor will damage it. Follow the instructions carefully.
- '09-10 models: Connect battery power to terminal No. 1 of the recirculation control motor, and ground terminal No. 2; the recirculation control motor should run smoothly, and stop at Fresh. If it doesn't, reverse the connections; the recirculation control motor should run smoothly, and stop at Recirculate. When the recirculation control motor stops running, disconnect battery power immediately.
- '11 models: Connect battery power to terminal No. 1 of the recirculation control motor, and ground terminal No. 2; the recirculation control motor should run smoothly, and stop at Recirculate. If it doesn't, reverse the connections; the recirculation control motor should run smoothly, and stop at Fresh. When the recirculation control motor stops running, disconnect battery power immediately.
- If the recirculation control motor did not run in step 2, remove it, then check the recirculation control linkage and door for smooth movement.
- If the linkage and door move smoothly, replace the recirculation control motor (see RECIRCULATION CONTROL MOTOR REPLACEMENT ).
- If the linkage or door stick or bind, repair them as needed.
- If the recirculation control motor runs smoothly, go to step 5.
- Use a digital multimeter with an output of 1 mA or less at the 20 kΩ range. With the recirculation control motor running as in step 2, check for continuity between terminals No. 3, 4, and 5 and terminal No. 7 individually. There should be continuity for a moment at each terminal as the motor moves past the switch's terminal.
- If there is no continuity for a moment at each terminal, replace the recirculation control motor (see RECIRCULATION CONTROL MOTOR REPLACEMENT ).