The PCM controls the shift solenoid valves ON and OFF. The conditions of the shift solenoid valves and positions of the shift valve are as follows:

The manual valve is moved to P, and line pressure (1) becomes line pressure (3) at the manual valve. Line pressure (3) passes through the reverse control valve, and becomes line pressure (3A), then flows to the servo valve. Line pressure (3A) pushes the servo valve to the reverse position. Line pressure (3) flows to the manual valve via the reverse CPC valve and shift valve A, and stops at the manual valve. Hydraulic pressure is not applied the clutches.

NOTE: When used, "left" or "right" indicates direction on the hydraulic circuit.
Fig 1: Hydraulic Pressure Flow Diagram - P Position
G06628638Courtesy of AMERICAN HONDA MOTOR CO., INC.