Enable Conditions
| Condition | Minimum | Maximum |
|---|---|---|
| IMA motor speed | 500 rpm | 1,500 rpm |
| IMA motor driving torque | 10 N.m (1 kgf.m, 7.2 lbf.ft) | - |
| No active DTCs set (prevents monitor from running) | P0602 (91), P0602 (92), P062F (60), P06B1, P0A1B, P0A3C, P0A3F, P0A5E, P0A5F, P0A61, P0A62, P0A64, P0A65, P0A78, P0A7E, P0AC0, P0AC1, P0AC2, P0AE1, P0B0F, P0B10, P0B11, P0BE6, P0BEA, P0BEE, P0BFD, P1437, P1570, P1575, P1586, P15A5, P1634, U0038, U0311, U0312, U1204 | |