| C10 |
BLK/RED |
IG1 (IGNITION SIGNAL) |
Detects ignition signal |
With ignition switch ON (II): battery voltage |
| C13 |
YEL/RED |
VCC1 (SENSOR VOLTAGE) |
Provides sensor reference voltage |
With ignition switch ON (II): about 5.0 V |
| C14 |
GRN/WHT |
SG1 (SENSOR GROUND) |
Sensor ground |
Less than 0.2 V at all times |
| C35 |
WHT |
IMACANH (CAN COMMUNICATION SIGNAL HIGH) |
Detects communication signal to motor control module (MCM) |
With ignition switch ON (II): pulses |
| C36 |
RED |
IMACANL (CAN COMMUNICATION SIGNAL LOW) |
Detects communication signal to motor control module (MCM) |
With ignition switch ON (II): pulses |
| C39 |
BLU |
PDN (CVT DRIVEN PULLEY PRESSURE SENSOR) |
Detects CVT driven pulley pressure sensor signal |
Driven pulley pressure 0 MPa: about 0 V Driven pulley pressure 2 MPa: about 5.0 V |
| C44 |
BRN/YEL |
LG1 (LOGIC GROUND) |
Ground circuit for PCM |
Less than 0.2 V at all times |
| C49 |
BRN/YEL |
LG2 (LOGIC GROUND) |
Ground circuit for PCM |
Less than 0.2 V at all times |