A/F Sensor (Bank 2)
DTC P0154: Monitor ID $05: Test ID $80
| OBD Monitor ID | $05 | Test ID | $80 | Unit and Scaling ID | $11 |
|---|---|---|---|---|---|
| DTC | P0154 | ||||
| Test Description | Check of A/F sensor "non-activation" by monitoring the sensor non-activation time. | ||||
| Store Timing | Normal judgment/Failure judgment | ||||
| Conversion to Engineering Units | Measured value: Output value (Decimal) x 0.1 (sec.) The lowest limit value: Not applicable The highest limit value: Output value (Decimal) x 0.1 (sec.) |
||||
DTC P0154: Monitor ID $05: Test ID $82
| OBD Monitor ID | $05 | Test ID | $82 | Unit and Scaling ID | $0B |
|---|---|---|---|---|---|
| DTC | P0154 | ||||
| Test Description | Check of A/F sensor "non-activation" by monitoring the sensor cell voltage. | ||||
| Store Timing | Failure judgment | ||||
| Conversion to Engineering Units | Measured value: Output value (Decimal) x 0.01 (V) The lowest limit value: Output value (Decimal) x 0.01 (V) The highest limit value: Output value (Decimal) x 0.01 (V) |
||||
DTC P2197: Monitor ID $05: Test ID $8D
| OBD Monitor ID | $05 | Test ID | $83 | Unit and Scaling ID | $8D |
|---|---|---|---|---|---|
| DTC | P2197 | ||||
| Test Description | Check of the A/F sensor "too lean" by monitoring the A/F sensor signal. | ||||
| Store Timing | Normal judgment/Failure judgment | ||||
| Conversion to Engineering Units | Measured value: Output value (Decimal) x 0.003906 (mA) The lowest limit value: Output value (Decimal) x 0.003906 (mA) The highest limit value: Not applicable |
||||
DTC P2A03: Monitor ID $05: Test ID $84
| OBD Monitor ID | $05 | Test ID | $84 | Unit and Scaling ID | $8D |
|---|---|---|---|---|---|
| DTC | P2A03 | ||||
| Test Description | Check of A/F sensor rationality by monitoring the sensor signal during fuel cut condition. | ||||
| Store Timing | Normal judgment/Failure judgment | ||||
| Conversion to Engineering Units | Measured value: Output value (Decimal) x 0.003906 (mA) The lowest limit value: Output value (Decimal) x 0.003906 (mA) The highest limit value: Output value (Decimal) x 0.003906 (mA) |
||||
DTC P0153: Monitor ID $05: Test ID $85
| OBD Monitor ID | $05 | Test ID | $85 | Unit and Scaling ID | $01 |
|---|---|---|---|---|---|
| DTC | P0153 | ||||
| Test Description | Response check of A/F sensor by monitoring the amplitude of filtered sensor signal during stable driving condition. | ||||
| Store Timing | Normal judgment/Failure judgment | ||||
| Conversion to Engineering Units | Measured value: No unit The lowest limit value: No unit The highest limit value: Not applicable |
||||
DTC P1174: Monitor ID $05: Test ID $86
| OBD Monitor ID | $05 | Test ID | $86 | Unit and Scaling ID | $8D |
|---|---|---|---|---|---|
| DTC | P1174 | ||||
| Test Description | Check of A/F sensor "out of range" by monitoring the sensor signal. | ||||
| Store Timing | Normal judgment/Failure judgment | ||||
| Conversion to Engineering Units | Measured value: Output value (Decimal) x 0.003906 (mA) The lowest limit value: Output value (Decimal) x 0.003906 (mA) The highest limit value: Not applicable |
||||
DTC P0154: Monitor ID $05: Test ID $87
| OBD Monitor ID | $05 | Test ID | $87 | Unit and Scaling ID | $14 |
|---|---|---|---|---|---|
| DTC | P0154 | ||||
| Test Description | Check of A/F sensor "non-activation" by monitoring the sensor element resistance during A/F feedback control. | ||||
| Store Timing | Failure judgment | ||||
| Conversion to Engineering Units | Measured value: Output value (Decimal) x 1 (W) The lowest limit value: Not applicable The highest limit value: Output value (Decimal) x 1 (W) |
||||
DTC P0154: Monitor ID $05: Test ID $88
| OBD Monitor ID | $05 | Test ID | $88 | Unit and Scaling ID | $0B |
|---|---|---|---|---|---|
| DTC | P0154 | ||||
| Test Description | Check of A/F sensor "non-activation" by monitoring the sensor cell voltage during A/F feedback control. | ||||
| Store Timing | Failure judgment | ||||
| Conversion to Engineering Units | Measured value: Output value (Decimal) x 0.01 (V) The lowest limit value: Output value (Decimal) x 0.01 (V) The highest limit value: Output value (Decimal) x 0.01 (V) |
||||