Recirculation Control Motor Replacement

  1. Open the glove box. While holding the glove box, release the glove box stops on each side from the dashboard by pushing them in, then lower the glove box (see step 1 on GLOVE BOX STRIKER REPLACEMENT ).
  2. Disconnect the 7P connector (A) from the recirculation control motor (B). Remove the self-tapping screws and the recirculation control motor from the blower unit.
    Fig 1: Identifying Recirculation Control Motor And 7P Connector
    G08094435Courtesy of AMERICAN HONDA MOTOR CO., INC.
  3. Install the motor in the reverse order of removal. Make sure the pin on the motor is properly engaged with the linkage. After installation, make sure the motor runs smoothly.