Oil Pump Overhaul: Inspection
NOTE:
Refer to the Exploded View if needed during this procedure.
- Remove the screws from the pump housing, then separate the pump housing and the oil pump cover.
- Check the inner rotor-to-outer rotor radial clearance between the inner rotor (A) and the outer rotor (B). If the inner rotor-to-outer rotor radial clearance exceeds the service limit, replace the oil pump assembly.
Inner Rotor-to-Outer Rotor Radial Clearance
Standard (New): 0.06-0.16 mm (0.003-0.006 in)
Service Limit: 0.20 mm (0.007 in)
- Check the pump housing-to-rotor axial clearance between the rotors (A) and the pump housing (B). If the pump housing-to-rotor axial clearance exceeds the service limit, replace the oil pump assembly.
Housing-to-Rotor Axial Clearance
Standard (New): 0.02-0.06 mm (0.001-0.002 in)
Service Limit: 0.15 mm (0.005 in)
- Check the pump housing-to-outer rotor radial clearance between the outer rotor (A) and the pump housing (B). If the pump housing-to-outer rotor radial clearance exceeds the service limit, replace the oil pump assembly.
Pump Housing-to-Outer Rotor Radial Clearance
Standard (New): 0.100-0.175 mm (0.004-0.006 in)
Service Limit: 0.20 mm (0.007 in)
- Inspect both rotors and the pump housing for scoring or other damage. Replace the oil pump assembly, if necessary.
- Check that the oil pump turns freely.