LEMON Manuals: Even more car manuals for everyone
Home >> Honda >> 2011 >> Insight Base >> Repair and Diagnosis >> Engine Mechanical >> Cooling System (Mechanical) >> Cooling System >> Fan Motor Test

Fan Motor Test

  1. Disconnect the 2P connectors from the radiator and the A/C condenser fan motors.
    Fig 1: Identifying A/C Condenser Fan Motors 2P Connectors
    G06429084Courtesy of AMERICAN HONDA MOTOR CO., INC.
  2. Test each motor by connecting battery power to terminal No. 2 and ground to terminal No. 1.
  3. If the motor fails to run, or does not run smoothly, replace it (see TENSIONER PULLEY REPLACEMENT  ).