Daytime Running Lights
The MICU controls the daytime running lights system based upon the input signals from each switch and the B-CAN data.
INPUT AND OUTPUT REFERENCE TABLE
| - | Input | Output |
|---|---|---|
| MICU | IG1 power supply IG2 power supply Combination light switch (OFF) Combination light switch (ON) Combination light switch (PASSING) Combination light switch (DIMMER) |
Left daytime running light Right daytime running light |
| B-CAN | Parking brake signal IG1 meter signal Automatic lighting signal |
DRL messages |