N Position

WARNING: This page is about a different car, the 2008 Honda Pilot, 2007 Honda Pilot, and 2006 Honda Pilot. However, it is still accessible from the selected car via links, so may be relevant.

The PCM controls the shift solenoid valves. The conditions of the shift solenoid valves and positions of the shift valve are as follows:

Line pressure (1) passes through the manual valve and becomes line pressure (25). Line pressure (25) stops at shift valve D. Line pressure (1) also flows to the modulator valve and becomes modulator pressure (6). Modulator pressure (6) flows to the shift solenoid valves, A/T clutch pressure control solenoid valves A and B, and A/T clutch pressure control solenoid valve C. Under this condition, the hydraulic pressure is not applied to the clutches.

NOTE: When used, "left" or "right" indicates direction on the hydraulic circuit.
Fig 1: Hydraulic Flow Diagram - N Position
G05593816Courtesy of AMERICAN HONDA MOTOR CO., INC.