LEMON Manuals: Even more car manuals for everyone
Home >> Honda >> 2007 >> Ridgeline RT >> Repair and Diagnosis >> Body & Frame >> Door Locks >> Keyless/Power Door Locks/Security System >> Door Key Cylinder Switch Test

Door Key Cylinder Switch Test

  1. Remove the driver's door panel (see COMPONENT LOCATION INDEX - FRONT DOOR ).
  2. Disconnect the 3P connector from the key cylinder switch.
    Fig 1: Identifying Door Key Cylinder Switch Connector Terminals
    G05592999Courtesy of AMERICAN HONDA MOTOR CO., INC.
  3. Check for continuity between the terminals.
    • There should be continuity between the No. 2 and No. 3 terminals when the door key cylinder switch is in LOCK position.
    • There should be no continuity between the No. 2 and No. 3 terminals when the door key cylinder switch is in the neutral or UNLOCK position.
    • There should be continuity between the No. 1 and No. 2 terminals when the door key cylinder switch is in UNLOCK position.
    • There should be no continuity between the No. 1 and No. 2 terminals when the door key cylinder switch is in the neutral or LOCK position.
  4. If the continuity is not as specified, replace the door key cylinder assembly (see FRONT DOOR OUTER HANDLE REPLACEMENT ).