SHO2S Heater (Bank 2)
DTC P0161: Test ID $1A: Component ID $89
| Test ID | $1A | Test Limit Type and Component ID | $89 |
| DTC | P0161 | ||
| Test Description | Circuit check of secondary oxygen sensor heater by monitoring the sensor output current during heater on. | ||
| Store Timing | Normal judgement/Failure judgement | ||
| Conversion to Engineering Units | Measured value: Output value (Decimal) x 0.01 (A) The lowest limit value: Output value (Decimal) x 0.01 (A) The highest limit value: Not applicable |
||
DTC P0161: Test ID $1B: Component ID $09
| Test ID | $1B | Test Limit Type and Component ID | $09 |
| DTC | P0161 | ||
| Test Description | Circuit check of secondary oxygen sensor heater by monitoring the sensor output current during heater on. | ||
| Store Timing | Normal judgement/Failure judgement | ||
| Conversion to Engineering Units | Measured value: Output value (Decimal) x 0.01 (A) The lowest limit value: Not applicable The highest limit value: Output value (Decimal) x 0.01 (A) |
||