LEMON Manuals: Even more car manuals for everyone
Home >> Honda >> 2003 >> Pilot EX >> Repair and Diagnosis >> Engine Performance >> Mode 6 - 2003 HONDA >> Mode $06 Information By Test >> SHO2S Heater (Bank 1)

SHO2S Heater (Bank 1)

DTC P0141: Test ID $18: Component ID $85

Test ID $18 Test Limit Type and Component ID $85
DTC P0141
Test Description Circuit check of secondary oxygen sensor heater by monitoring the sensor output current during heater on.
Store Timing Normal judgement/Failure judgement
Conversion to Engineering Units Measured value: Output value x 26.7 (mA)
The lowest limit value: Output value x 26.7 (mA)
The highest limit value: Not applicable
DTC P0141: Test ID $19: Component ID $05

Test ID $19 Test Limit Type and Component ID $05
DTC P0141
Test Description Circuit check of secondary oxygen sensor heater by monitoring the sensor output current during heater on.
Store Timing Normal judgement/Failure judgement
Conversion to Engineering Units Measured value: Output value x 26.7 (mA)
The lowest limit value: Not applicable
The highest limit value: Output value x 26.7 (mA)
DTC P0141: Test ID $18: Component ID $86

Test ID $18 Test Limit Type and Component ID $86
DTC P0141
Test Description Circuit check of secondary oxygen sensor heater by monitoring the sensor output current during heater on.
Store Timing Normal judgement/Failure judgement
Conversion to Engineering Units Measured value: Output value x 7.23 (mA)
The lowest limit value: Output value x 7.23 (mA)
The highest limit value: Not applicable
DTC P0141: Test ID $19: Component ID $06

Test ID $19 Test Limit Type and Component ID $06
DTC P0141
Test Description Circuit check of secondary oxygen sensor heater by monitoring the sensor output current during heater on.
Store Timing Normal judgement/Failure judgement
Conversion to Engineering Units Measured value: Output value x 7.23 (mA)
The lowest limit value: Not applicable
The highest limit value: Output value x 7.23 (mA)
DTC P0141: Test ID $18: Component ID $87

Test ID $18 Test Limit Type and Component ID $87
DTC P0141
Test Description Circuit check of secondary oxygen sensor heater by monitoring the sensor output current during heater on.
Store Timing Normal judgement/Failure judgement
Conversion to Engineering Units Measured value: Output value x 16.552 (mA)
The lowest limit value: Output value x 16.552 (mA)
The highest limit value: Not applicable
DTC P0141: Test ID $19: Component ID $07

Test ID $19 Test Limit Type and Component ID $07
DTC P0141
Test Description Circuit check of secondary oxygen sensor heater by monitoring the sensor output current during heater on.
Store Timing Normal judgement/Failure judgement
Conversion to Engineering Units Measured value: Output value x 16.552 (mA)
The lowest limit value: Not applicable
The highest limit value: Output value x 16.552 (mA)
DTC P0141: Test ID $18: Component ID $89

Test ID $18 Test Limit Type and Component ID $89
DTC P0141
Test Description Circuit check of secondary oxygen sensor heater by monitoring the sensor output current during heater on.
Store Timing Normal judgement/Failure judgement
Conversion to Engineering Units Measured value: Output value (Decimal) x 0.01 (A)
The lowest limit value: Output value (Decimal) x 0.01 (A)
The highest limit value: Not applicable
DTC P0141: Test ID $19: Component ID $09

Test ID $19 Test Limit Type and Component ID $09
DTC P0141
Test Description Circuit check of secondary oxygen sensor heater by monitoring the sensor output current during heater on.
Store Timing Normal judgement/Failure judgement
Conversion to Engineering Units Measured value: Output value (Decimal) x 0.01 (A)
The lowest limit value: Not applicable
The highest limit value: Output value (Decimal) x 0.01 (A)