  1. Remove the radiator fan relay from the main under-hood fuse/relay box, and test it (see POWER RELAY TEST ).

    Is the relay OK? 

    1. YES  - Go to step  2.
    2. NO  - Replace the radiator fan relay.
  2. Remove the radiator fan switch, and test it (see RADIATOR FAN SWITCH TEST  ).

    Is the radiator fan switch OK? 

    1. YES  - Go to step  3.
    2. NO  - Replace the radiator fan switch.
  3. Disconnect engine control module (ECM) connector A (32P) and the under-hood fuse/relay box 16P connector.
  4. Check for continuity between the radiator fan switch 2P connector terminal No. 2 and body ground.

    Is there continuity? 

    1. YES  - Repair a short in the wire between the radiator fan switch 2P connector terminal No. 2 and main under-hood fuse/relay box.
    2. NO  - Replace the main under-hood fuse/relay box.
    Fig 1: Checking Continuity Between Radiator Fan Switch 2P Connector Terminal No. 2 & Body Ground