LEMON Manuals: Even more car manuals for everyone
Home >> Honda >> 1998 >> Civic HX, Standard >> Repair and Diagnosis >> Brakes >> Traction Control >> Anti-Lock Brake System >> Operation >> Abs Modulator Unit >> Pressure Reduction Mode

Pressure Reduction Mode

Inlet solenoid valve is closed and outlet solenoid valve is open. Brake fluid pressure at wheels flows through outlet solenoid valve to brake fluid reservoir.