Vacuum Switch C
- Disconnect vacuum hose No. 15 to the control box at the vacuum manifold and connect a vacuum pump to the hose. Apply vacuum to switch. Check for continuity between Black/Yellow and Blue/Black wire terminals of control box 6-pole connector.
- Continuity should be present when a vacuum above 12 in. Hg is applied. If there is no voltage, replace the vacuum switch C and retest.