TDC Sensor
- Release connector of crank angle sensor. Measure resistance between Brown terminal and Blue terminal at sensor. Resistance should read 0.65-0.85 k/ohms.
- Measure insulation resistance between Brown/Blue terminal and crank angle sensor housing. Resistance should read 100 k/ohms or more.