Vacuum Advance
Remove distributor cap. Disconnect vacuum hoses from distributor advance/retard diaphragm. Connect vacuum pump to diaphragm. Gradually draw a vacuum while watching breaker plate movement. Check for smooth operation without binding. If pump indicates a loss of vacuum, replace diaphragm unit. Turn breaker plate right and left to check for free movement.