Pressure Limit Valve

During anti-lock operation, pressure in rear wheel hydraulic circuit is modulated by EBCM through pressure limit valve. This prevents rear wheel lock, while providing maximum stopping and directional stability. Pressure limit valve is located under the master cylinder and actually consists of 2 valves: a dump valve which releases pressure into an accumulator and an isolation valve which maintains rear wheel hydraulic pressure.

During anti-lock operation, a series of rapid pulsations (caused by the fluctuating position of the pressure limit valve) will be felt at the brake pedal. These pulsations, in conjunction with possible tire "chirping" (on dry pavement), are considered normal during anti-lock operation and will cease when normal braking is resumed or vehicle comes to a complete stop.