Code 25, Oxygen Sensor Circuit, Lean Exhaust Indicated: Notes
ECM supplies approximately .45 volt between ECM terminals OX+ and OX1. If voltage is measured with a 10-megohm DVOM, reading may be as low as .32 volt. The O2 sensor produces a varying voltage as engine reaches normal operating temperature. Voltage will vary between.1-.9 volt.
The O2 sensor will not produce voltage until sensor reaches 600°F (316°C). When sensor is less than normal operating temperature, an open loop condition exists.
NOTE:
Test numbers refer to test numbers on diagnostic chart.
- Code 25 sets when O2 sensor signal voltage on Black wire remains below .2 volt for one minute or more with system in closed loop.