| Main action |
- Monitor the video streaming state of the camera
|
- Poor connection in wiring harness
- Open or short in power circuit
- Open or short in right camera video line
- Open in ground circuit
|
| Prerequisite condition |
- Turn the ignition switch ON (between 9V and 16V)
|
| Threshold Value |
- When there is no right camera's sync signal
|
| Diagnostic Time |
- DTC sets if the faulty is lasting over 3 second
|
| Troubleshooting Hints |
- Substitute function is not available
|
| DTC clearing time |
- DTC cleared after resolving the failure.
|