T1 Accessory DC/AC Power Inverter Module (KI6)
Connector Part Information
|
Terminal Part Information
| Terminal Type ID | Terminated Lead | Diagnostic Test Probe | Terminal Removal Tool | Service Terminal | Tray Name | Core Crimp | Insulation Crimp |
|---|---|---|---|---|---|---|---|
| I | Not Required | J-35616-35 (VT) | No Tool Required | Not Required | Not Required | Not Required | Not Required |
| II | Not Required | J-35616-64B (LT BU) | No Tool Required | Not Required | Not Required | Not Required | Not Required |
| Pin | Size | Color | Circuit | Function | Terminal Type ID | Option |
|---|---|---|---|---|---|---|
| 1 | 0.75 | RD | 5684 | 120 V AC Phase B | I | - |
| 2 - 3 | - | - | - | Not Occupied | - | - |
| 4 | 1.5 | RD/WH | 2040 | Battery Positive Voltage | I | - |
| 5 | 0.75 | BK | 5683 | 120 V AC Phase A | I | - |
| 6 | 0.35 0.35 |
BU/BN BU/BN |
6807 6807 |
DC To AC Inverter Control DC To AC Inverter Control |
II II |
KI6 KI7 |
| 7 | - | - | - | Not Occupied | - | - |
| 8 | 1.5 | BK | 2250 | Ground | I | - |