LEMON Manuals: Even more car manuals for everyone
Home >> GMC >> 2019 >> Sierra 2500 HD Base, 2D Pickup, Gas >> Repair and Diagnosis >> Engine Performance >> System >> Engine Controls And Fuel - 6.0L (L96 LC8) - Repair Instructions >> Repair Instructions >> Fuel Pump Flow Control Module Replacement (CNG) >> Removal Procedure

Removal Procedure

    WARNING:

    Natural gas is highly flammable. In order to reduce the risk of fire and personal injury, keep sparks, flames, and smoking materials away from the vehicle while you perform the Compressed Natural Gas (CNG) fuel system service.

    WARNING:

    The Compressed Natural Gas (CNG) system operates at pressures up to 24820 kPa (3600 psi). Relieve the CNG fuel system pressure before servicing CNG fuel system components in order to reduce the risk of fire and personal injury.

  1. Disconnect the negative battery cable. Refer to Battery Negative Cable Disconnection and Connection (L96 LC8)Battery Negative Cable Disconnection and Connection (L83)Battery Negative Cable Disconnection and Connection (Dual Battery)Battery Negative Cable Disconnection and Connection (L5P) .
  2. Remove the red tab (1) and disconnect the electrical connector (2) from the control module.
    GM2921018Courtesy of GENERAL MOTORS COMPANY
  3. Remove the fasteners (1) from the fuel pump control module bracket.
    GM2921022Courtesy of GENERAL MOTORS COMPANY
  4. Remove the fuel pump control module (2) from the bracket.