Circuit/System Testing
- Ignition OFF and all vehicle systems OFF, disconnect the harness connector at the S45B Liftgate Control Switch-Interior, ignition ON.
- Verify the scan tool Liftgate Mode Switch parameter is greater than 300 counts.
- Ignition OFF, disconnect the harness connector at the K39 Liftgate Control Module.
- Test for infinite resistance between the signal circuit terminal 3 and ground
- If less than infinite resistance, repair the short to ground on the circuit.
- If infinite resistance, replace the K39 Liftgate Control Module
- Go to next step: If greater than 300 counts
- Install a 3 A fused jumper wire between the signal circuit terminal 3 and the ground circuit terminal 1.
- Verify the scan tool Liftgate Mode Switch parameter is less than 5 counts.
- Ignition OFF, disconnect the harness connector at the K39 Liftgate Control Module.
- Test for less than 2 Ω in the signal circuit end to end.
- If 2 Ω or greater, repair the open/high resistance in the circuit.
- If less than 2 Ω, replace the K39 Liftgate Control Module
- Go to next step: If less than 5 counts
- Test or replace the S45B Liftgate Control Switch-Interior.