Component Testing
Dynamic Test
- Ignition OFF, disconnect the X1 harness connector at the K33 HVAC control module.
- Install a 3 A fused jumper wire between the control terminal 17 and 12 V. Install a jumper wire between the ground terminal 23 and ground.
- Verify the rear defog indicator turns ON.
- If the rear defog indicator does not turns ON
Replace the K33 HVAC control module.
- Go to next step: If the rear defog indicator does turns ON
- If the rear defog indicator does not turns ON
- All OK