Initialization Sequence
The initialization sequence cycles each solenoid valve and the pump motor, as well as the necessary relays, for approximately forty milliseconds to check component operation. One of the checks performed is the adaptive pressure calibration that occurs when the engine is running and the brake pedal is not applied. The adaptive pressure calibration will cycle each of the six isolation valves to verify valve operation. The initialization sequence may be heard and felt while it is taking place, and is considered part of normal system operation. The active test is initiated by the electronic brake control module at the start of the ignition cycle and the speed of the fastest wheel exceeds 16 km/h (10 MPH). If a fault condition is detected the electronic brake control module sets a DTC.