Circuit/System Testing
- Ignition/Vehicle & All vehicle systems » Off
- Disconnect the electrical connector:X2 X53A Fuse Block - Rear Body
- Test for less than 10 Ω between the test points:Ground circuit terminal 34 X2 & Ground
- If 10 Ω or greater
- Ground Connection»Disconnect
- Test for less than 2 Ω between the test points:Ground circuit terminal 34 X2 & Ground Connection
- If 2 Ω or greater » Repair the open/high resistance in the circuit.
- If less than 2 Ω » Repair the open/high resistance in the ground connection.
- If less than 10 Ω
- Connect the electrical connector: X2 X53A Fuse Block - Rear Body
- Disconnect the electrical connector: X2 K33 HVAC Control Module
- Ignition » On / Vehicle » In Service Mode
- Momentarily connect a 3 A fused jumper wire between the test points:Control circuit terminal 19 X2 & B+
Verify the component turns On and Off when connecting and disconnecting the jumper wire:E18 Rear Defogger Grid
- If the component does not turn On and Off
- Ignition/Vehicle » Off & Remove » Jumper wire(s)
- Disconnect the electrical connector:X2 X53A Fuse Block - Rear Body
- Ignition » On / Vehicle » In Service Mode
- Test for less than 1 V between the test points:Control circuit terminal 19 X2 @Control module harness & Ground
- If 1 V or greater » Repair the short to voltage on the circuit.
- If less than 1 V
- Ignition/Vehicle » Off
- Test for infinite resistance between the test points:Control circuit terminal 19 X2 @Control module harness & Ground
- If less than infinite resistance » Repair the short to ground on the circuit.
- If infinite resistance
- Test for less than 2 Ω between the test points:Control circuit terminal 19 X2 @Control module harness & Terminal 40 X2 @Fuse Block Harness
- If 2 Ω or greater » Repair the open/high resistance in the circuit.
- If less than 2 Ω » Test or replace the component:X53A Fuse Block - Rear Body
- If the component turns On and Off
- Replace the component:K33 HVAC Control Module
NOTE:
It may take up to 2 min for all vehicle systems to power down before an accurate ground or low reference circuit continuity test can be performed.