Circuit/System Testing
NOTE:
Circuit/System Verification must be performed before proceeding with Circuit/System Testing.
- Ignition OFF, disconnect the KR73 ignition main relay.
- Test for less than 10 Ω between the ground circuit terminal 85 and ground.
- If greater than the specified range, test the ground circuit for an open/high resistance.
- Ignition ON, verify that a test lamp illuminates between the Ignition circuit terminal 86 and ground.
- If the test lamp does not illuminate, test the Ignition circuit for an open/high resistance. If the circuit tests normal replace the K9 BCM.
- Ignition OFF, reconnect the KR73 ignition main relay.
- Disconnect the harness connector at the P16 Instrument Cluster.
- Ignition ON, verify that a test lamp illuminates between the ignition terminal 31 and ground.
- If the test lamp does not illuminate and the Ignition fuse is good, test the ignition circuit for an open/high resistance. If the circuit tests normal, replace the KR73 ignition main relay. If the ignition fuse is open, test the ignition circuit for a short to ground. If the circuit tests normal, replace the P16 instrument cluster.
- If all circuits test normal, replace the P16 instrument cluster.