Circuit/System Testing
DTC B023A
- Ignition OFF and all vehicle systems OFF, disconnect the harness connector at the components listed below. It may take up to 2 min for all vehicle systems to power down.
- M37 Mode Door Actuator
- M4 Air Inlet Door Actuator
- M6 Air Temperature Door Actuator
- Disconnect the harness connector at the K33 HVAC Control Module.
- Test for infinite resistance between the K33 HVAC Control Module 12 V reference circuit terminal 15 and ground.
- If less than infinite resistance
Repair the short to ground on the circuit.
- If infinite resistance
- If less than infinite resistance
- Ignition ON.
- Test for less than 1 V between the K33 HVAC Control Module 12 V reference circuit terminal 15 and ground.
- If 1 V or greater
Repair the short to voltage on the circuit.
- If less than 1 V
- If 1 V or greater
- Connect the harness connector at the K33 HVAC Control Module, ignition ON.
- Clear all DTCs.
- Verify DTC B023A is not set.
- If the DTC is set.
Replace the K33 HVAC Control Module.
- If the DTC is not set.
- If the DTC is set.
- Verify DTC B023A does not set after connecting each of the components listed below one at a time and operating them through their full range.
- M37 Mode Door Actuator
- M4 Air Inlet Door Actuator
- M6 Air Temperature Door Actuator
- If the DTC sets after connecting one of the components
Replace the component that was connected immediately before the DTC set.
- If the DTC does not set
- All OK.
DTC B0223, B0233, or B0408
- Ignition OFF, disconnect the harness connector at the appropriate door actuator and disconnect the harness connectors at the K33 HVAC Control Module, ignition ON.
- Verify a test lamp illuminates between the B+ circuit terminal 2 and ground.
- If the test lamp does not illuminate
- Disconnect the X3 harness connector at the K33 HVAC Control Module.
- Test for infinite resistance between the B+ circuit and ground.
- If less than infinite resistance, repair the short to ground on the circuit.
- If infinite resistance.
- Test for less than 2 Ω in the B+ circuit end to end.
- If 2 Ω or greater, repair the open/high resistance in the circuit.
- If less than 2 Ω, replace the K33 HVAC Control Module.
- If the test lamp illuminates
- Test for less than 1 V between ground and the control circuits listed below:
- Control Circuit - terminal 1
- Control Circuit - terminal 3
- Control Circuit - terminal 4
- Control Circuit - terminal 6
- If 1 V or greater
Repair the short to voltage on the circuit.
- If less than 1 V
- Ignition OFF.
- Test for infinite resistance between ground and the control circuits listed below:
- Control Circuit - terminal 1
- Control Circuit - terminal 3
- Control Circuit - terminal 4
- Control Circuit - terminal 6
- If less than infinite resistance
Repair the short to ground on the circuit.
- If infinite resistance
- Disconnect the X3 harness connector at the K33 HVAC Control Module.
- Test for less than 2 Ω end to end in the circuits listed below:
- Control Circuit - terminal 1
- Control Circuit - terminal 3
- Control Circuit - terminal 4
- Control Circuit - terminal 6
- B+ Circuit - terminal 2
- If 2 Ω or greater
Repair the open/high resistance in the circuit.
- If less than 2 Ω
- Test or replace the actuator.
- Verify the symptom or DTC was corrected.
- If the symptom or DTC was not corrected
Replace the K33 HVAC Control Module.
- If the symptom or DTC was corrected
- If the symptom or DTC was not corrected
- All OK.
NOTE:
Before replacing an actuator, verify that there are no mechanical issues with the air control door and any associated components.