Circuit/System Testing

  1. Ignition OFF, disconnect the K55 DEFOG RR relay.
  2. Test for less than 30 Ω between the ground circuit terminal 85 and ground.
    • If greater than the specified range, test the ground circuit for an open/high resistance.
  3. Engine running, verify a test lamp does not illuminate between the control circuit terminal 87 and ground.
    • If the test lamp illuminates, test the control circuit for a short to voltage.
  4. Verify a test lamp illuminates between the B+ circuit terminal 30 and ground.
    • If the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance.
  5. Ignition OFF, disconnect the X2 harness connector at the E18 rear window defogger grid.
  6. Test for less than 30 Ω between the ground circuit terminal 1 and ground.
    • If greater than the specified range, test the ground circuit for an open/high resistance.
  7. Connect the X2 harness connector at the E18 rear window defogger grid.
  8. Engine running, connect a 30 A fused jumper wire between the B+ circuit terminal 30 and the control circuit terminal 87. Verify the E18 rear window defogger grid is activated.
    • If the E18 rear window defogger grid does not activate, test the control circuit for a short to ground or an open/high resistance. If the circuit tests normal, test or replace the E18 rear defogger grid.
  9. Connect a test lamp between the control circuit terminal 86 and the ground circuit terminal 85.
  10. Command the Rear Defog ON and OFF with a scan tool, the test lamp should turn ON and OFF when changing between the commanded states.
    • If the test lamp is always ON, test the control circuit for a short to voltage. If the circuit tests normal, replace the K33 HVAC control module.
    • If the test lamp is always OFF, test the control circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the K33 HVAC control module.
  11. If all circuits test normal, test or replace the K55 DEFOG RR relay.