Circuit/System Testing
- Ignition OFF, disconnect the harness connector at the VES actuator.
- Test for greater than 1 Mega ohm between the ground control terminal 1 and ground.
- If less than the specified range, test the ground control circuit for a short to ground. If the circuit tests normal, replace the EBCM.
- Ignition ON, with a scan tool command the actuator ON 10%, verify less than 50 ohms.
- If greater than the specified range, test the ground control circuit for an open/high resistance. If the circuit tests normal, replace the EBCM.
- Test for less than 2 volts between the voltage control terminal 2 and ground with the actuator command state at 0.
- If greater than the specified range, test the voltage control circuit for a short to voltage. If the circuit tests normal, replace the EBCM.
- If not the specified value, test the control circuit for a short to ground.
- If all circuits test normal, test or replace the VES actuator.