Component Testing
- Ignition OFF, disconnect the harness connector at the RPA display.
- Connect a 10A fused jumper wire between 12V voltage supply circuit terminal A and B+.
- Connect a 10A fused jumper wire between control circuit terminal and ground of the appropriate LED listed below:
- Left amber LED control circuit terminal B
- Center amber LED control circuit terminal C
- Red LED control circuit terminal D
- Verify that the appropriate LED illuminates.
- If the component does not perform as specified, replace the RPA display.