Removal Procedure
- Disconnect the engine harness electrical connector from the generator battery control module.
- Remove the negative battery cable. Refer to Battery Negative Cable Replacement (4.3L) or Battery Negative Cable Replacement (4.8L, 5.3L, 6.0L, and 8.1L) or Battery Negative Cable Replacement (6.6L) .
- Cut the tie straps and electrical tape attaching the generator battery control module to the battery cable.
- Squeeze the negative battery cable branches together.
- Slide the generator battery control module off of the negative battery cable.
IMPORTANT:
Note the orientation of the generator battery control module prior to removal.